Wind Induced Vibrations on Light Standards
The authors were recently
involved in a project for which site work consisted of curb and gutter,
sidewalks, parking lot paving, and light poles with foundations in the
parking lot and along the roadway. Approximately five months prior to
ribbon cutting, the client noticed that nearly all of the light poles
were swaying considerably under wind velocities of approximately 17 to
28 mph, with gusts up to 46 mph. Figure 1 illustrates the observed
light pole movement, which had a magnitude of approximately 8 to 12
inches.
Figure 1: Observed light pole movement.
The
very next day, the client discovered one of the light poles on the
ground, with what appeared to be fatigue cracking at the weld between
the light pole base plate and the pole itself (Figure 2). The client
took down the remaining poles to prevent further failures. Fortunately,
there were no injuries associated with the light pole failure, since
this event occurred during the night when the construction crew was not
present.
Figure 2: Light pole base failure.
Review
of the light pole submittal revealed that the subcontractor had
proposed a different size and type of pole than what had been
originally selected - a 30-foot tall, 6-inch square aluminum pole.
Instead, the subcontractor proposed a 30-foot tall, 4-inch square steel
pole, which was approved since the 4-inch pole more than adequately met
the performance specification according to the manufacturer’s
literature.
Consultations with the light
pole supplier and manufacturer indicated that the failure of the light
pole was "most likely" due to wind-induced harmonic resonance of the
light pole, and subsequent fatigue cracking of the weld between the
base plate and the pole. The light pole manufacturer responded to a
request for replacement light poles by saying that its standard
one-year warranty does not cover "naturally occurring harmonic
vibration light pole failures". Additional calls to various light pole
manufacturers revealed that none of them warrant failure due to
harmonic vibration.
It is important to
note that the failed light pole met all of the manufacturer’s
requirements, and had been properly selected and installed based on
their criteria. Many light pole manufacturers publish wind speed maps
and light pole selection criteria for their products. The following is
a common light pole selection procedure:
1)
Select the light fixture, and obtain its effective projected area (EPA)
and weight. The EPA is the area that is loaded by wind. This
information is located on the fixture cut sheet.
2)
Determine the number of light fixtures and any special mounting methods
(arm or bracket) to be installed on the pole. Obtain the EPA and weight
for any arms or brackets from the corresponding cut sheets.
3) Add up the EPA and the weights of all fixtures, arms, and brackets.
4)
Select the design wind speed for the project location from the light
pole manufacturer’s wind map. Typically, this is a fastest mile wind
speed, which is different from the current building code values for a
3-second gust. Tables exist for converting between the two.
5)
Select a pole, and compare both the EPA and weights of the fixture with
the allowable EPA and weights for that specific pole. If the actual EPA
and weights of the fixtures are less than the allowable EPA and maximum
weight listed on the pole cut sheet, then the pole meets the
requirements.
In the case of this
project, the light poles met these criteria and yet still failed under
the destructive effects of vibration under modest wind speeds; the
design wind speed was 80 mph (fastest mile). In fact, when the wind
speed matches the natural frequency of the light pole, there will
"always" be resonance as a result. This will lead to fatigue cracking
of the weld at the base plate to pole interface. Only in certain
circumstances are light poles designed to resist fatigue, according to
AASHTO Standard Specifications for Structural Supports for Highway
Signs, Luminaires and Traffic Signals - specific "high level" lighting
structures, along with overhead cantilevered traffic signal and sign
structures. AASHTO indicates that common light poles do not normally
exhibit fatigue problems, but as our example indicates, such failures
can occur.
Rather than investing time and
energy into fatigue analysis and mitigation in common light poles, a
cost-effective approach is to minimize the probability of resonance by
eliminating characteristics that enhance resonance. Two contributing
factors to light pole resonance are height and fixture arrangement. One
pole manufacturer indicates that light poles with a fixture EPA of less
than 2.0 (very few fixtures) at a height of 25 feet or greater have an
increased probability of resonance. While such a slender light pole can
withstand the maximum design wind speeds, which generally are above 70
mph, it is susceptible to wind-induced vibration, which typically
occurs around 20-40 mph.
As an example,
consider the vibration of a flagpole exposed to wind. When there is no
flag on the pole, it is quite common to hear cables "banging" against
the pole. This is due to movement or vibration of the pole. However,
when there is a flag at the top of the pole, the wind loading applied
to the flag acts to dampen the resonant movement of the pole,
eliminating the "banging" sound. (Incidentally, flagpoles have a
different foundation anchoring system that typically does not include a
base plate or welds. See the NAAMM Guide Specifications for Design of
Metal Flagpoles for more information on flagpole design).
Consequently,
the use of shorter light poles with multiple light fixtures will
generally reduce the chances of resonance. The shorter length provides
a more rigid structure, and having more fixtures at the top equates to
greater wind loading. This wind loading and the fixture weight at the
top act as dampers to reduce resonant movement of the pole.
Additionally,
although no shape is exempt from wind-induced resonance, it has been
noted that round (or octagonal) tapered light poles are less
susceptible to it than square ones. The natural frequency of a tapered
light pole varies along its length, which makes it less likely to
develop overall resonance from a constant wind. This is evident in the
common types of poles used for highway lighting, flagpoles, and traffic
control/signage structures.
Further, the
geographic location of a light pole may also contribute to the
steady-state, low wind speeds that result in light pole resonance. It
has been noted that features such as unobstructed flat land or
low-level mountains, where wind can be channeled through an area, may
contribute to light pole resonance, as well as turbulence created by
aircraft or vehicular traffic.
Many light
pole manufacturers have attempted to minimize the problem of light pole
resonance by offering factory- or field-installed dampers. A damper
will essentially change the natural frequency of the light pole such
that it will not coincide with a specific wind speed range. In many
cases, these dampers are hanging weights that are installed either on
the surface of the light pole or inside it. Dampers are not a cure-all
for resonance, because they only change the range of wind speeds that
can cause wind-induced resonance.
Based
on the information above, the following recommendations have been
collected from various light pole manufacturers’ literature and should
be considered to reduce the probability of wind-induced resonance:
1) Use round (preferably tapered) light poles less than 25 feet tall, with a 6-inch minimum diameter.
2) Use a minimum of two fixtures per pole to provide some weight at the top to help dampen the light pole.
3)
Include in the pole specifications a requirement for factory - or
field-installed vibration dampers to be provided by the light pole
manufacturer.
4) Contact the light pole
manufacturer when there are site-specific concerns that should be
considered during light pole design.
5)
Provide specific wind loading information in the documents, and
indicate whether wind loading is based on a 3-second gust or fastest
mile wind speed.
Periodic maintenance and
inspection of a light pole can help determine if wind-induced vibration
is a concern. Items to be inspected include the weld between the base
plate and the light pole shaft and loosening or damage of the light
fixture, as well as frequent lamp replacement. The client should be
notified of the potential problem - possibly as part of a
specifications-required O&M manual - and a maintenance plan should
be implemented. If there is concern during periodic maintenance, the
light pole manufacturer should be contacted, in addition to a
structural engineer to assist in determining whether wind-induced
vibration is the cause of the concern.
There
is one more question: If harmonic resonance is prevalent during or
after construction, who picks up the repair bill? Since the cause of
wind-induced resonance is ultimately the wind, it is difficult to argue
that the light pole manufacturer, contractor, client, or engineer is at
fault. They can minimize the probability of wind-induced resonance, but
not eliminate it. In this example, the light pole supplier replaced all
16 poles on the project. The project continued with minimal disruption
thanks to the light pole supplier, whose personnel should be commended
for their professional response to the issue. It is in the best
interests of all parties involved to work together to minimize the
probability of wind-induced resonance and to put in place measures to
monitor any future concerns.▪