GENERAL EGRESS HEADROOM REQUIREMENTS:

1003.2 Ceiling height. The means of egress shall have a ceiling height of not less than 7 feet 6 inches (2286 mm).

Exceptions:
1. Sloped ceilings in accordance with Section 1208.2.
2. Ceilings of dwelling units and sleeping units within residential occupancies in accordance with Section 1208.2.
3. Allowable projections in accordance with Section 1003.3.
4. Stair headroom in accordance with Section 1009.2.
5. Door height in accordance with Section 1008.1.1.

1003.3.1 Headroom. Protruding objects are permitted to extend below the minimum ceiling height required by Section 1003.2 provided a minimum headroom of 80 inches (2032 mm) shall be provided for any walking surface, including walks, corridors, aisles and passageways. Not more than 50 percent of the ceiling area of a means of egress shall be reduced in height by protruding objects.

Exception: Door closers and stops shall not reduce headroom to less than 78 inches (1981 mm).

Visitor Comments
No visitor comments posted. Post a comment
Post Comment for "Minimum Egress Headroom or Protruding Ceiling Objects"
To post a comment for this article, simply complete the form below. Fields marked with an asterisk are required.
   Your Name:
   Email Address:
* Your Comment:
* Enter the code below:
 
Related Articles
No related articles were found.
Attachments
No attachments were found.

Home ::: Services ::: Tools::: Ordering ::: About Us ::: Support ::: Login

Click Here To Contact Us  ::: Email: office@engexp.com ::: Privacy Policy  

ENGINEERING EXPRESS®
160 SW 12th Ave #106 Deerfield Beach, FL 33442
Phone: (954) 354-0660  |  Fax: (954) 354-0443 | Toll Free: 1-866-ENG-EXP1
www.engineeringexpress.com or just www.engexp.com
© 2006-2010 Frank L. Bennardo PE, Inc
A Florida Corporation
Information, methodology, logos, photos, and trademarked names
on this website may not be used, reproduced, distributed, or modified without
the written permission of Frank L. Bennardo, P.E., Inc.